The alliance
of the enterprises
For today the "ONYX" enterprise is a co-founder
of the alliance of the enterprises, into which "POLYTEXHPROM",
Ltd., "Yug-Viol", Ltd. and SPBC "KVS",
Ltd. also entered.
The principal production activity of the enterprises
of the alliance is manufacturing of electric motors,
complicated domestic appliances, woodworking equipment,
and also of pollution-free fuel - fuel briquettes
and billets, equipment for their manufacturing as
well. |
|
|
|
|
Electric Motors -- Type: OKA…/56R… |
|
The single-phase capacitor motors with distributed
winding of OKA…/56P… type are manufactured in accordance
with GOST 16264.1-85 and meant for driving actuators
of different appliances:
washing machines;
juicers;
centrifuges;
driving
actuator of passenger elevator doors;
medical
facilities;
industrial
equipment.
Basic Technical
Data
|
Ord.№ |
Index Name |
Standard
|
| Modification
|
OKA 90-
4/56RK |
OKA 120-
4/56RM, RKL |
OKA 120-
2/56RKA |
OKA 120-
2/56RK |
OKA 150-
4/56RKL |
OKA 180-
4/56RKL |
| 1 |
Rated Voltage,
V |
220 |
220 |
220 |
220 |
220 |
220 |
| 2 |
Nominal capacity,W |
90 |
120 |
120 |
120 |
150 |
180 |
| 3 |
Current frequency,
Hz |
50 |
50 |
50 |
50 |
50 |
50 |
| 4 |
Rated rotational
speed, rpm |
1380
±41 |
1380
±41 |
2720
±82 |
2720
±82 |
1380
±41 |
1380
±41 |
| 5 |
Rated current,
A, not more |
1.00 |
1.20 |
1.40 |
1.10 |
1.40 |
1.60 |
| 6 |
Efficiency |
0.50 |
0.53 |
0.47 |
0.56 |
0.57 |
0.57 |
| 7 |
Power factor,
no less |
0.80 |
0.85 |
0.80 |
0.85 |
0.88 |
0.88 |
| 8 |
Maximum torque
to nominal torque ratio, no less |
1.4 |
1.4 |
2.2 |
1.5 |
1.5 |
1.5 |
| 9 |
Locked-rotor
torque to nominal torque ratio, no less |
0.55 |
0.55 |
1.68 |
0.55 |
0.55 |
0.55 |
| 10 |
Minimum torque
to nominal torque ratio, no less |
0.50 |
0.50 |
1.65 |
0.50 |
0.55 |
0.55 |
| 11 |
Breakaway starting
current to rated current ratio, at most |
2.3 |
2.4 |
2.8 |
2.8 |
2.8 |
2.8 |
| 12 |
Capacitor capacitance, μF |
6 |
6 |
12 |
8 |
8 |
8 |
| 13 |
Mass, kg, no
more than 2 |
2.8 |
3.1 |
3.1 |
3.1 |
3.6 |
4.1 |
| 14 |
Motor winding
superheat temperature relative to ambient temperature,
°C, at most |
85 |
85 |
85 |
85 |
85 |
85 |
| 15 |
Maximum safe
winding heat temperature, °C, at most |
130 |
130 |
130 |
130 |
130 |
130 |
Overall and mounting dimensions can be
customized.
|
|